Skip to main content
ICA 1975 · MIDA · MITI · Act 737 · MDA manufacturer licence

Manufacturing licence for a medical device factory in Malaysia: two licences with the same name.

MITI’s manufacturing licence depends on how big your company is. MDA’s manufacturer licence depends on what you make. A medical device factory can need both, and confusing them is how projects get a MIDA approval and still cannot ship a single device. Here is who needs which, the criteria and fees, and the order to do things in.

01 MDA Registration02 GDPMD + Licensing03 ISO 13485 QMS04 MDSAP05 CE / FDA Export

Short answer: the MITI manufacturing licence (Industrial Co-ordination Act 1975, applied for through MIDA) is needed by any manufacturer with shareholders’ funds of RM2.5 million or more or 75 or more full-time employees; smaller companies can apply for an exemption. The MDA manufacturer licence (Medical Device Act 2012, Act 737) is needed by every medical device manufacturer that sells, imports or exports registered devices, whatever its size: it needs ISO 13485, costs RM250 + RM4,000 in MDA fees and takes 14–21 working days once complete. Each device must also be registered, or exempted if it is made only for export.

Checked against MIDA, MDA and Customs on 17 November 2026

The two licences side by side

MITI manufacturing licenceMDA manufacturer licence
LawIndustrial Co-ordination Act 1975Medical Device Act 2012 (Act 737), s.15 and s.18
Apply to / issued byApply online to MIDA; approved by MITIApply in MDA’s MeDC@St system; issued by MDA
Who needs itAny manufacturer with shareholders’ funds of RM2.5 million or more, or 75 or more full-time paid employeesAny medical device manufacturer that imports, exports or places registered devices on the Malaysian market, whatever its size
Main conditionsCapital investment per employee of at least RM140,000; at least 80% Malaysians in the full-time workforce; at least 25% managerial, technical and supervisory staff or value added of at least 40%A certified ISO 13485 quality management system; one licence per role (manufacturer, importer, distributor) since 1 July 2024
Smaller companiesBelow both thresholds: apply for an exemption (online ICA10 application)No size exemption. Export-only devices can be exempted from registration and the licence under the Exemption Order 2024
MDA feesNot an MDA licenceRM250 application + RM4,000 licence; renewal RM200 + RM2,000; valid 3 years
Covers the products?No. It says nothing about whether a device may be soldNo. Each device still needs its own MDA registration

ICA thresholds and approval criteria from MIDA’s Approval and Licensing page and its Guideline on Application for Manufacturing Licence (3 November 2022). MDA fees from the Fifth Schedule of the Medical Device Regulations 2012 as amended.

The MITI manufacturing licence (ICA 1975)

The ICA defines manufacturing activity as “the making, altering, blending, ornamenting, finishing or otherwise treating or adapting any article or substance with a view to its use, sale, transport, delivery or disposal”, including the assembly of parts, but not activity normally associated with retail or wholesale trade. Making, assembling or sterilising devices in your own plant falls inside that definition; buying finished devices and reselling them does not.

Do you cross the threshold?

  • Shareholders’ funds of RM2.5 million or more: paid-up capital, reserves (excluding revaluation reserves), share premium and the profit and loss appropriation balance.
  • 75 or more full-time paid employees: people working at least six hours a day and 20 days a month for 12 months, paid directly by the company, including directors other than those paid only to attend board meetings. Workers outsourced from a third party are not counted as yours.

What MIDA looks at

  • Capital investment per employee (CIPE) of at least RM140,000, counting fixed assets and 10 years of rent for land and buildings.
  • At least 80% Malaysians in the full-time workforce; employing foreign workers, including outsourced workers, follows current policy.
  • At least 25% managerial, technical and supervisory (MTS) staff, or value added of at least 40%.
  • A project consistent with national economic and social objectives.

Applications go online through MIDA’s InvestMalaysia portal and are assessed through a self-assessment and self-declaration mechanism meant to speed up approval. A company below both thresholds can apply for an exemption (ICA10); MIDA says an exemption letter makes it eligible to apply for import duty exemptions on machinery, equipment and raw materials, sales tax exemptions and investment incentives, subject to their criteria.

The MDA manufacturer licence (Act 737)

This is the licence that decides whether your factory can sell a single device in Malaysia. Section 15 of Act 737 bars an establishment, which includes a manufacturer, from importing, exporting or placing a registered device on the market without an establishment licence; the penalty is a fine of up to RM200,000, up to 3 years in prison, or both. What it takes:

  1. Work out who the legal manufacturer is. Under Act 737 it is whoever puts the device on the market under its own name, even if a subcontractor makes it. A contract manufacturer building for a foreign brand is that brand’s subcontractor. See manufacturing consultant.
  2. Certify an ISO 13485 system. It has to run long enough to produce records before the certification body’s audits, so this is the longest step: several months for an SME. See ISO 13485.
  3. Apply for the manufacturer licence in MeDC@St: RM250 + RM4,000, 14–21 working days once complete, valid 3 years. If you also import components or finished devices, that is a separate importer licence.
  4. Register each device you sell in Malaysia: the CSDT, conformity assessment by a CAB for Class B, C and D, then MDA. See MDA registration.
  5. For export, ask MDA for a Certificate of Free Sale or Manufacturing Certificate for registered devices, or use the export-only exemption and an Export Certificate.

GMP for medical devices means ISO 13485

Customers and agents often ask a Malaysian device maker for a “GMP certificate”. For medical devices, the quality system MDA works with is ISO 13485: it supports the manufacturer licence, CABs audit against it, and it is the base for MDSAP, CE marking under EU MDR and the US FDA’s QMSR. The GMP regimes you may have read about are for other products: NPRA licenses and inspects factories making medicines, traditional products and supplements, and food factories are certified against MS 1514 (our sister site explains MeSTI and food GMP). A device plant needs those only if it also makes those products.

Export-oriented plants: LMW status

Many Malaysian device plants export almost everything. The Royal Malaysian Customs Department licenses export-oriented manufacturers as a Licensed Manufacturing Warehouse (LMW) under section 65A of the Customs Act 1967, which concerns import duty and sales tax on materials and goods. LMW status is about customs, not product approval: devices made under it still need MDA registration, or an export-only exemption under paragraph 3(1)(f) of the Medical Device (Exemption) Order 2024 (on application to MDA, RM500 per device nomenclature, valid 5 years). The exemption ends as soon as any unit is sold in Malaysia.

Setting up a medical device plant: the order that saves time

  1. Decide the regulatory model first: own brand or contract manufacturing, Malaysian market or export only. It decides who needs which MDA licence and whether devices need registration or an export-only exemption.
  2. Incorporate and go to MIDA: the ICA manufacturing licence if you cross either threshold, otherwise the ICA10 exemption, plus any incentives you qualify for.
  3. Build the ISO 13485 system while the plant is fitted out, so validation records exist when production starts and the certification audit can follow quickly.
  4. MDA manufacturer licence as soon as the certificate is issued (14–21 working days).
  5. Register the devices or obtain export-only exemption letters; for registered devices, a Certificate of Free Sale for overseas customers.
  6. Customs facilities such as LMW for an export-oriented plant.
Jawapan ringkas · Bahasa Malaysia

Adakah kilang peranti perubatan memerlukan lesen pengilangan MITI dan lesen MDA?

Mungkin kedua-duanya. Lesen pengilangan MITI (Akta Penyelarasan Perindustrian 1975, mohon melalui MIDA) diperlukan jika dana pemegang saham RM2.5 juta ke atas atau 75 pekerja sepenuh masa atau lebih; syarikat lebih kecil boleh memohon pengecualian. Lesen pengilang MDA (Akta 737) pula diperlukan oleh setiap pengilang peranti perubatan yang menjual, mengimport atau mengeksport peranti berdaftar, tanpa mengira saiz: perlu ISO 13485, fi MDA RM250 + RM4,000. Setiap peranti juga perlu didaftarkan. WhatsApp 010-206 2070.

FAQ

Frequently asked questions

Do I need a manufacturing licence to manufacture in Malaysia?
Under the Industrial Co-ordination Act 1975, a company engaged in manufacturing needs a manufacturing licence from MITI (the Ministry of Investment, Trade and Industry) if it has shareholders’ funds of RM2.5 million or more, or 75 or more full-time paid employees. Applications go to MIDA online. Smaller companies can apply to MIDA for an exemption instead. This is separate from any product licence: a medical device manufacturer also needs MDA’s manufacturer licence under Act 737, whatever its size.
What is the difference between the MITI manufacturing licence and the MDA manufacturer licence?
The MITI licence regulates manufacturing activity in general and is triggered by company size; MIDA receives the application and MITI approves it. The MDA licence regulates medical devices and is triggered by the product: section 15 of Act 737 bars an establishment, including a manufacturer, from importing, exporting or placing a registered device on the Malaysian market without an establishment licence. A large device factory needs both; a small one usually needs only MDA’s, plus an ICA exemption letter if it wants MIDA facilities.
How do I apply for a manufacturing licence through MIDA?
Online through MIDA’s InvestMalaysia portal. MIDA has evaluated applications received from 26 March 2021 through its online portal, and the application is assessed under a self-assessment and self-declaration mechanism. The government’s guidelines for approval ask for capital investment per employee of at least RM140,000, at least 80% Malaysians in the full-time workforce, and either at least 25% managerial, technical and supervisory staff or value added of at least 40%.
What is the ICA exemption, and why apply for it?
A company below both thresholds can apply to MIDA for exemption from the manufacturing licence using the online ICA10 application. MIDA says companies with an exemption letter are eligible to apply for government facilities such as import duty exemptions on machinery, equipment and raw materials under the Customs Duties (Exemption) Order 2017, sales tax exemptions under the Sales Tax (Persons Exempted From Payment Of Tax) Order 2018, and investment incentives, subject to their criteria.
What does the MDA manufacturer licence need, and what does it cost?
An ISO 13485 quality management system, certified, and an application in MDA’s MeDC@St system. MDA charges RM250 to apply plus RM4,000 for the manufacturer licence, valid 3 years (renewal RM200 plus RM2,000), and processes a complete application in 14–21 working days. Since 1 July 2024 each role is a separate licence, so a manufacturer that also imports needs an importer licence too. Every device it sells in Malaysia must also be registered.
Is GMP required for a medical device factory in Malaysia?
For medical devices the quality system MDA works with is ISO 13485: it supports the manufacturer licence and it is what conformity assessment bodies audit. When a customer asks a device maker for “GMP”, ISO 13485 certification is normally the answer, and it is also the base for MDSAP, EU MDR and the US FDA’s QMSR. Separate GMP regimes apply to factories making medicines, traditional products and supplements (NPRA) or food (MOH, MS 1514).
We only make devices for export. Do we still need the MDA licence?
Devices made only for export can be exempted from Malaysian registration under paragraph 3(1)(f) of the Medical Device (Exemption) Order 2024, on application to MDA (RM500 per device nomenclature, valid 5 years), and paragraph 4 of the Order lifts the establishment licence for whoever imports or exports those devices. The exemption ends the moment any unit is sold in Malaysia. Your customers’ regulators will still expect ISO 13485 at your site.
Does a Licensed Manufacturing Warehouse (LMW) replace MDA approval?
No. LMW is a Customs facility: the Royal Malaysian Customs Department licenses export-oriented manufacturers under section 65A of the Customs Act 1967. It concerns duties and taxes on materials and goods, not product safety. MDA’s licence, registration or export-only exemption still applies to the devices you make.

Make sure the plant can ship on day one

Tell us what you will make and where it will be sold. We map the licences, build the ISO 13485 system, file the MDA manufacturer licence and register or exempt each device: RM7,500 for ISO 13485 + licence (our fee), registrations from RM3,800 all-in.

WhatsApp